|
ECS Linux服务器内存不足导致安装mysql5.6失败的分析解决
发布日期:2015-12-24 19:12:56
问题描述: 使用Ubuntu14.0464位操作系统,安装mysql5.6时报错: 3983 [Note] InnoDB:Completedinitializationofbufferpool 3983 [Note] InnoDB:HighestsupportedfileformatisBarracuda. 3983 [Note] InnoDB:128rollbacksegment(s)areactive. 3983 [Note] InnoDB:Waitingforpurgetostart 3983 [Note] InnoDB:5.6.19started;logsequencenumber1600607 [ERROR] Aborting 3983 [Note] Binlogend 3983 [Note] InnoDB:FTSoptimizethreadexiting. 3983 [Note] InnoDB:Startingshutdown... 3983 [Note] InnoDB:Shutdowncompleted;logsequencenumber1600617 3983 [Note] start:Jobfailedtostart invoke-rc.d:initscriptmysql,action"start"failed. dpkg:errorprocessingpackagemysql-server-5.6(--configure): subprocessinstalledpost-installationscriptreturnederrorexitstatus1 Processingtriggersforureadahead(0.100.0-16)... Errorswereencounteredwhileprocessing: mysql-server-5.6 E:Sub-process/usr/bin/dpkgreturnedanerrorcode(1) 分析解决: 增加swap之后问题仍然没有得到解决,经排查分析,因为InnoDB引擎需要更大物理内存支持,当前系统物理内存不足导致出现错误提示,程序不能继续执行。建议升级或者更换为1G及1G以上内存配置后,再次进行安装测试。
|